创刊于1987年, 双月刊
主管:

江西理工大学

主办:

江西理工大学
江西省有色金属学会

ISSN:1674-9669
CN:36-1311/TF
CODEN YJKYA9

电感耦合等离子体原子发射光谱法测定钇铁合金中14种稀土杂质元素

陈绯宇, 张少夫, 温世杰

陈绯宇, 张少夫, 温世杰. 电感耦合等离子体原子发射光谱法测定钇铁合金中14种稀土杂质元素[J]. 有色金属科学与工程, 2017, 8(6): 121-124. DOI: 10.13264/j.cnki.ysjskx.2017.06.020
引用本文: 陈绯宇, 张少夫, 温世杰. 电感耦合等离子体原子发射光谱法测定钇铁合金中14种稀土杂质元素[J]. 有色金属科学与工程, 2017, 8(6): 121-124. DOI: 10.13264/j.cnki.ysjskx.2017.06.020
CHEN Feiyu, ZHANG Shaofu, WEN Shijie. Determination of 14 rare earth elements in yttrium-iron alloy by inductively coupled plasma atomic emission spectrometry[J]. Nonferrous Metals Science and Engineering, 2017, 8(6): 121-124. DOI: 10.13264/j.cnki.ysjskx.2017.06.020
Citation: CHEN Feiyu, ZHANG Shaofu, WEN Shijie. Determination of 14 rare earth elements in yttrium-iron alloy by inductively coupled plasma atomic emission spectrometry[J]. Nonferrous Metals Science and Engineering, 2017, 8(6): 121-124. DOI: 10.13264/j.cnki.ysjskx.2017.06.020

电感耦合等离子体原子发射光谱法测定钇铁合金中14种稀土杂质元素

基金项目: 

工信部2016年第一批行业标准修订计划[2016-58]文, 计划号为2016-0336T-XB 

详细信息
    通讯作者:

    张少夫(1959-),男, 高工, 主要从事稀土元素分析检测等方面研究,E-mail:zhangshaofu126@126.com

  • 中图分类号: O657.31

Determination of 14 rare earth elements in yttrium-iron alloy by inductively coupled plasma atomic emission spectrometry

  • 摘要: 电感耦合等离子体原子发射光谱法测定钇铁合金中14种稀土杂质元素.用近似基体匹配法校正基体效应的影响,通过共存元素对稀土谱线的干扰实验,优选了测定分析线.考察了基体变化对测定结果的影响.确定了14种稀土元素的测定范围为0.005 0 %~0.20 %,测定结果的相对标准偏差(n=11)为0.88 %~7.20 %,标加回收率为97.44 %~103.28 %.该方法快速,准确,可用于产品的检测.
    Abstract: The contents of 14 rare earth elements in yttrium iron alloy were determined by inductively coupled plasma atomic emission spectrometry.The matrix effect was adjusted by approximate matrix matching method. The spectral lines are optimized through analyzing the interference of coexisting elements to rare earth elements. The influence of matrix changes on the determination results was investigated. The determination range of 14 kinds of rare earth elements was 0.005 0 %~0.20 %. The relative standard deviations (n=11) of the determination results were 0.88 %~7.20 %, and the recoveries were 97.44 %~103.28 %. The method is fast and accurate and can be used for product testing.
  • 高纯纳米级氧化铝水性胶体是制备激光晶体、精细陶瓷和优质催化剂的前驱物[1],笔者利用由醇铝水解得到的高纯纳米氧化铝水分散液为研究对象,选取了合成宝石常用的几种矿化剂,用电导法分析矿化剂对纳米氧化铝水分散液介电性能的影响。旨在通过实验,一是了解高纯纳米级氧化铝水性胶体的一些电化学行为;二是考察矿化剂对其电导率的影响,为探究人工合成宝石新原料做些尝试。

    DDS-307型电导率仪(上海精密科学仪器有限公司),GKCR114可控硅控温水浴锅,SC202型电热恒温干燥箱,自制电导池等。

    碳酸氢钠,碳酸钠,碳酸钾,碳酸氢钾,溴化钾,试剂均为分析纯。超纯水(电导率为0.63 μs/cm)。高纯纳米氧化铝水分散液。

    (1) 纳米氧化铝水分散液的合成。以醇铝为原料, 在一定条件下进行水解缩聚反应得到。外观特征为乳白色胶体,稳定性好,粒径分布均匀。

    (2) 纳米氧化铝水分散液的升温水热处理。将装有纳米氧化铝水分散(原液)的聚四氟乙烯高压密封罐置于恒定温度的烘箱内,在自生压力下水热处理一定时间。

    (3) 电导率的测定。每一样品的电导率在298 K或303 K恒温水浴中保温30 min后测定,平行测定3次,取其平均值。所用方法原理参照GB l576—2001。

    一定浓度的纳米氧化铝水分散(原液)经110、120、130、140、150 ℃水热处理24 h后得到5个样品,在30 ℃下测其电导率,其结果见图 1

    图  1  纳米氧化铝水分散液的电导率随升温处理的变化

    在升温处理实验中,发现样品的粘度随处理温度的升高而逐渐变小,透明度逐渐增大,样品的这种粘度逐渐变小和胶团的解缔变小,使带电颗粒运动时的阻力减弱,体系的导电性能得到增强,所以在所做实验的温度范围内,产生图 1中样品电导率随处理温度的升高而呈线形增大的结果。另外,从原液和150 ℃样品得到的扫描电镜图(图 2图 3)与X射线衍射图(图 4图 5)对照显示:分散体系的胶粒增大,结晶趋于完善。

    图  2  原液扫描电镜图
    图  3  150 ℃样品扫描电镜图
    图  4  原液X射线衍射图
    图  5  150℃样品X射线衍射图

    在25 ℃下(电导率测定温度除特别说明外均相同),测定不同质量分数试样的电导率值,其结果见图 6

    图  6  试样的电导率与质量分数的关系

    图 6可以看出,在实验较低浓度范围内分散液电导率随浓度都呈良好的线性关系,这与电解质的溶液导电理论很相似,即溶液的电导率与溶液中的离子浓度成比例,但在实验较高浓度范围内分散液电导率随浓度所呈现的线性斜率发生了改变。

    从查阅的人工宝石合成文献中,了解到所采用的矿化剂有碳酸钾、碳酸钠、溴化钾、碳酸氢钾和碳酸氢钠等[2-3],本实验选用了碳酸钠、碳酸氢钾和溴化钾3种,比较它们对纳米氧化铝水分散液电导率的影响,同时为了考察矿化剂浓度对纳米氧化铝水分散液电导率的影响,每种矿化剂又配成4~5个浓度系列,其结果见图 7~图 9

    图  7  不同浓度的碳酸钠对分散液电导率的影响
    图  8  不同浓度的碳酸氢钾对分散液电导率的影响
    图  9  不同浓度的溴化钾对分散液电导率的影

    图 7~图 9可以看出,各种矿化剂的加入都使分散液的电导率有不同程度的增大,随着加入矿化剂浓度的增加(在一定实验范围内),分散液的电导率呈梯度增加。矿化剂对分散液电导率的增大影响,是因为矿化剂属于完全离解的电解质溶液,随着浓度增加,可导电成分也成比例增加,故电导率随矿化剂浓度的增加呈梯度增加。

    以一定质量分数的纳米氧化铝水分散液为原样,按不同种类矿化剂配制成一个系列试样。将这些试样放入可控硅控温水浴锅,在30、35、40、50、60、70 ℃下恒温30 min后,分别测它们的电导率,见图 10

    图  10  温度在原样+不同矿化剂下对电导率的影响

    图 10中可以看出两点变化,一是加入相同浓度矿化剂试样的电导率随着温度的升高而升高,温度越高上升趋势越大;二是不同的矿化剂(浓度相等)在相同的温度下对体系电导率的影响不同,并表现出一定的规律性。电导率在这两方面的变化,可分别解释为:电导率受温度变化的影响,是因为在加入矿化剂的纳米氧化铝体系中,可导电的物质主要是胶体颗粒和无机盐离子,随温度的升高,导电颗粒和离子的运动动能增大,电导率增大;电导率因不同矿化剂变化的影响,与离子的本性有关,如正、负离子价数和离子半径大小。在水溶液中,离子都是水化的,在电荷相同的情况下,离子半径愈小水化程度(即离子的水化数)愈大,水化后的离子半径就愈大,因此在溶液中运动的阻力也增大,所以在离子电迁移速率上钾离子要大于钠离子,含钾的矿化剂对体系电导率的增大能力要大些;碳酸根离子强度要大于碳酸氢根,所以碱金属碳酸盐矿化剂对体系电导率的增大能力要比碳酸氢盐大些。

    (1)纳米氧化铝水性胶体在低粒子浓度范围内的电导率表现与低分子的电解质溶液相似,能用已有的电解质溶液理论来解释其导电性能。

    (2)分散液经升温水热处理后,体系的电导率增大,在实验温度范围内,电导率与处理的温度基本呈线形关系。

    (3)在分散液中加入矿化剂能大幅度增大体系的电导率,不同的矿化剂对体系的电导率影响不同,增大能力次序为:碳酸钾>碳酸钠>溴化钾>碳酸氢钾>碳酸氢钠。

  • 表  1   元素的分析线波长

    Table  1   Analytical spectral lines of the elements

    元素分析线/nm
    La408.672
    Ce413.765, 418.660
    Pr440.882, 417.937
    Nd401.225, 444.639
    Sm428.079, 443.432
    Ea381.967, 390.710
    Bd335.047, 376.839
    Tb440.547, 350.917
    Dy353.170
    Ho339.898, 345.600
    Er390.631
    Tm313.126
    Yb328.937
    Lu261.542
    下载: 导出CSV

    表  2   钇-铁基体变化对测定影响实验结果

    Table  2   Effects of matrix proportion in Y -Fe on the determination results

    元素参照值
    /(μg/mL-1)
    ω(Y):ω(Fe)=68%:32%
    测定值/(μg/mL-1)
    回收
    率%
    ω(Y):ω(Fe)=57%:43%
    测定值/(μg/mL-1)
    回收
    率%
    La5.0005.028100.565.024100.48
    Ce5.0005.092101.845.144102.88
    Pr5.0005.032100.644.99299.84
    Nd5.0004.99699.924.93698.72
    Sm5.0005.096101.925.152103.04
    Eu5.0004.92498.485.000100.00
    Gd5.0005.044100.885.124102.48
    Tb5.0004.94498.884.98099.60
    Dy5.0005.064101.285.164103.28
    Ho5.0005.020100.405.008100.16
    Er5.0004.96099.204.96499.28
    Tm5.0005.003100.065.152103.04
    Yb5.0005.076101.525.148102.96
    Lu5.0005.028100.565.160103.20
    下载: 导出CSV

    表  3   正交设计5因素4水平

    Table  3   Orthogonal test for instrumentation conditions

    水平功率/KW高压/V观察高度/mm冷却气流量/(L·min-1)载气流量/(L·min-1)
    10.956531211.50.60
    21.007031312.00.65
    31.057531412.50.70
    41.108031513.00.75
    较优值1.007531312.00.70
    下载: 导出CSV

    表  4   各元素的检出限和测定下限

    Table  4   Limit of detection level and low limit of determination of elements

    元素检出限/(μg·mL-1)测定下限/(μg·mL-1)
    La0.000030.0001
    Ce0.000850.0028
    Pr0.00160.0044
    Nd0.000140.00047
    Sm0.000200.00066
    Eu0.000020.000067
    Gd0.0000640.00021
    Tb0.00120.0041
    Dy0.000040.00015
    Ho0.000810.0025
    Er0.000040.00013
    Tm0.000030.00010
    Yb0.000010.00004
    Lu0.000060.00021
    下载: 导出CSV

    表  5   方法精密度试验

    Table  5   The precisions test of method

    元素平均值/(μg·mL-1)RSD/%
    La0.2873.58
    Ce0.3501.44
    Pr0.2015.81
    Nd1.1820.88
    Sm0.3852.21
    Eu<0.05/
    Gd0.1327.20
    Tb<0.05/
    Dy0.4301.37
    Ho0.1835.26
    Er<0.05/
    Tm<0.05/
    Yb<0.05/
    Lu<0.05/
      注:“/”指含量小于下限未计算出结果.
    下载: 导出CSV

    表  6   标准加入回收试验

    Table  6   Recovery test in standard addition method

    元素本底值
    /(μg·mL-1)
    加人量1.25 μg/mL加人量2.50 μg/mL加人量5.00 μg/mL
    检测值/(μg·mL-1)回收率/%检测值/(μg·mL-1)回收率/%检测值/(μg·mL-1)回收率/%
    La0.2871.52398.882.75198.565.433102.92
    Ce0.3501.621101.682.78697.445.22997.58
    P;0.2011.492103.282.771102.805.322102.42
    Nd1.1822.42599.443.64698.566.13198.98
    Sm0.3851.62298.962.942102.285.32398.76
    Eb<0.051.271101.682.532101.285.052101.04
    Gd0.1321.406101.922.58498.085.04798.30
    Tb<0.051.305104.402.563102.524.94098.80
    Dy0.4301.65998.322.88398.125.35298.44
    Ho0.1831.40197.442.65098.685.09998.32
    E;<0.051.259100.722.537101.485.083101.66
    Tm<0.051.23698.882.47298.884.95299.04
    Yb<0.051.265101.202.48699.445.038100.76
    Lu<0.051.24399.442.513100.525.069101.38
    下载: 导出CSV
  • [1] 胡文艳.钕铁硼永磁材料的性能及研究进展[J].现代电子技术, 2012, 35(2):151-152. http://www.cqvip.com/QK/92115X/199603/2416232.html
    [2] 陈晋.钕铁硼永磁材料的生产应用及发展前景[J].铸造技术, 2012(4):398-400. doi: 10.3969/j.issn.1674-5167.2015.21.017
    [3] 孟凡伟. 添加钆和钇的钕铁硼永磁材料制备工艺研究[D]. 赣州: 江西理工大学, 2009.
    [4] 陈海, 姜树斌, 杨贤木.用铁素体球铁铸造燃气轮机缸体类铸件[J].铸造技术, 2003(5):404-407. http://www.cqvip.com/QK/92080A/200702/24181145.html
    [5] 郭探, 王世栋, 叶秀深, 等.熔盐电解法制备稀土合金研究进展[J].中国科学:化学, 2012(9):1328-1336. https://cnki.com.cn/qikan-XTZZ201702015.html
    [6] 庞思明, 颜世宏, 李宗安, 等.我国熔盐电解法制备稀土金属及其合金工艺技术进展[J].稀有金属, 2011, 35(3):40-450. http://industry.wanfangdata.com.cn/yj/Detail/Periodical?id=Periodical_xyjs201103022
    [7] 朱玉华, 高兰.中国稀土标准汇编[M].北京:中国标准出版社, 2016.
    [8] 万家亮.现代光谱分析手册[M].武汉:华中师大出版社, 1987.
    [9] 冶金部科技科技情报所编译. 光谱线波长表[M]. 北京: 中国工业出版社, 1971.
    [10] 张少夫. ICP-AES法直接测定氧化钇中14个稀土元素[J].理化检验-化学分册, 1998, 34(1):25-27. http://cpfd.cnki.com.cn/Article/CPFDTOTAL-ZGXT201112001013.htm
    [11] 黎英, 刘鸿, 潘建忠.电感耦合等离子发射光谱法测定钆铁合金中稀土杂质量[J].有色金属科学与工程, 2011, 2(6):93-96. http://ysjskx.paperopen.com/oa/DArticle.aspx?type=view&id=20110621
    [12] 赵君威, 梅坛, 鄢国强, 等.电感耦合等离子体原子发射光谱分析中的光谱干扰及其校正的研究进展[J].理化检验-化学分册, 2013, 49(3):364-369. http://www.cqvip.com/QK/82430X/201517/665359808.html
    [13] 沈兰荪.光谱干扰校正方法的研究[M].北京:北京工业大学出版社, 1997.
    [14] 钱振彭, 张士道, 黄本立.发射光谱分析[M].北京:冶金工业出版社, 1977:289.
    [15] 尹祖平, 郝占之.氟盐体系电解制备钇铁合金几种原料的比较[J].稀土, 1991(3):70-72. http://www.cnki.com.cn/Article/CJFDTotal-XTZZ199103019.htm
    [16] 周西林, 李启华, 胡德声.实用等离子体发射光谱分析技术[M].北京:国防工业出版社, 2012:57.
    [17] 毛海梅, 陈碧波.正交试验在化学分析中的应用[J].海南矿冶, 1996(3):38-39. http://mall.cnki.net/magazine/article/HXJX201106008.htm
    [18] 肖明耀.误差理论与应用[M].北京:计量出版社, 1985:343.
    [19] 刘瑞江, 张业旺, 闻崇炜, 等.正交试验设计和分析方法研究[J].实验技术与管理, 2010, 27(9):52-55. http://www.docin.com/p-489865329.html
    [20] 辛仁轩.等离子体发射光谱分析[M]. 2版.北京:化学工业出版社, 2011:155.
  • 期刊类型引用(3)

    1. 陈绯宇,温世杰,郭才女. 稀土火法冶炼回收料中稀土总量的测定. 广东化工. 2023(17): 139-143 . 百度学术
    2. 曾江萍,王家松,朱悦,张楠,王娜,吴良英,魏双. 敞开酸溶-电感耦合等离子体质谱法测定铀矿石中15种稀土元素. 岩矿测试. 2022(05): 789-797 . 百度学术
    3. 张瑞霖,梁敏鉴,赵艳兵,樊鑫. 电感耦合等离子体质谱法测定铁铬铝合金中14种稀土元素. 冶金分析. 2021(02): 23-29 . 百度学术

    其他类型引用(0)

表(6)
计量
  • 文章访问数: 
  • HTML全文浏览量: 
  • PDF下载量: 
  • 被引次数: 3
出版历程
  • 收稿日期:  2017-07-06
  • 发布日期:  2017-12-30
  • 刊出日期:  2017-11-30

目录

/

返回文章
返回
x 关闭 永久关闭